STANDARDS - RENT OFFICE SPACE - EMPTY SPACE (6.FL) | |
---|---|
GROUNDWORK | monolithic reinforced concrete slab |
VERTICAL FRAMEWORK | reinforced concrete frame, reinforced concrete shield walls circumferentially filled with brick masonry |
VODOROVNÉ NOSNÉ KONŠTRUKCIE | železobetónové stropné dosky, monolitické železobetónové schodisko |
PERIPHERAL SURFACE / WINDOWS | glass facade AI system, opening windows with insulating 3-glass in the sense PD, color: anthracite |
DIVIDING PARTITIONS |
MAIN PARTITIONS walls separating corridor from room: SDK 125 mm; surface painting (white) INNER PARTITIONS between tenants: SDK 125 mm |
CEILINGS | reinforced concrete slab |
SURFACE FLOORS |
corridors, common areas - ceramic tiles office: anhydride screed terraces: concrete pavement on targets |
INTERIOR ENTRY DOORS | glazed door in aluminum frame |
ELECTRICAL INSTALLATION / LIGHTING |
sub-meters floor troughs preparation for wiring (connection points in the sense of PD) |
LOW POWER INSTALATION |
preparation - low-power connection for individual premises /
internet - in the sense of PD Note: floor troughs (see electrical installation point) |
CAMERA SYSTEM | terminal equipment within public buildings, in the sense of PD |
ELECTRONIC FIRE SIGNALING AND VOICE SIGNALING OF FIRE |
complete solution within an object, in the sense of PD |
HEATING / COOLING |
large radiant floor heating / cooling heat and hot water source: TEKO heat exchanger / heat source source of cold: groundwater for so-called freecooling in combination with chiller water - water note: ceiling cooling / cassette air conditioning (fancoil) under the standard |
AIR CONDITIONING | preparation for VZT - inlet and outlet pipes (connection points in the sense of PD) |
MEDICAL | preparation of ZTI - for the supply of media, water distribution and sewerage (connection points in the sense of PD) |
AUTOMATIC CONTROL (M and R) |
measurement of CO2, humidity, cooling and heating within
individual zones (in the space above 300 m2 within the
standard) control of ventilation |
ELEVATOR |
3 personal elevators (between 3.GF and 6.FL) 1 personal elevators (between 3.GF and 1.FL) 1 cargo elevator (between 3.GF and 6.FL) |
LIGHTING CONDUCTOR | solved within an object |
GARAGE STATION - internal | |
MARKING | by the number of the parking space |
ENTRANCE | through an opening ramp, via a chip |
THE FLOOR | "armored", abrasion resistant, waterproof, washable, concrete floorboard |
Note:
We offer the completion of the spaces
to the required standard.
It's possible to calculate the