STANDARDS - RENT OFFICE SPACE - EMPTY SPACE (6.FL)
GROUNDWORK monolithic reinforced concrete slab
VERTICAL FRAMEWORK reinforced concrete frame, reinforced concrete shield walls circumferentially filled with brick masonry
VODOROVNÉ NOSNÉ KONŠTRUKCIE železobetónové stropné dosky, monolitické železobetónové schodisko
PERIPHERAL SURFACE / WINDOWS glass facade AI system, opening windows with insulating 3-glass in the sense PD, color: anthracite
DIVIDING PARTITIONS MAIN PARTITIONS
walls separating corridor from room: SDK 125 mm; surface painting (white)
INNER PARTITIONS
between tenants: SDK 125 mm
CEILINGS reinforced concrete slab
SURFACE FLOORS corridors, common areas - ceramic tiles
office: anhydride screed
terraces: concrete pavement on targets
INTERIOR ENTRY DOORS glazed door in aluminum frame
ELECTRICAL INSTALLATION / LIGHTING sub-meters
floor troughs
preparation for wiring (connection points in the sense of PD)
LOW POWER INSTALATION preparation - low-power connection for individual premises / internet - in the sense of PD
Note: floor troughs (see electrical installation point)
CAMERA SYSTEM terminal equipment within public buildings, in the sense of PD
ELECTRONIC FIRE
SIGNALING AND VOICE
SIGNALING OF FIRE
complete solution within an object, in the sense of PD
HEATING / COOLING large radiant floor heating / cooling
heat and hot water source: TEKO heat exchanger / heat source
source of cold: groundwater for so-called freecooling in combination with chiller water - water
note: ceiling cooling / cassette air conditioning (fancoil) under the standard
AIR CONDITIONING preparation for VZT - inlet and outlet pipes (connection points in the sense of PD)
MEDICAL preparation of ZTI - for the supply of media, water distribution and sewerage (connection points in the sense of PD)
AUTOMATIC CONTROL (M and R) measurement of CO2, humidity, cooling and heating within individual zones (in the space above 300 m2 within the standard)
control of ventilation
ELEVATOR 3 personal elevators (between 3.GF and 6.FL)
1 personal elevators (between 3.GF and 1.FL)
1 cargo elevator (between 3.GF and 6.FL)
LIGHTING CONDUCTOR solved within an object
GARAGE STATION - internal
MARKING by the number of the parking space
ENTRANCE through an opening ramp, via a chip
THE FLOOR "armored", abrasion resistant, waterproof, washable, concrete floorboard

Note:
We offer the completion of the spaces to the required standard.
It's possible to calculate the price of budget for the completion of spaces (depends on the equipment) to rent price in agreement.